LP12-18 (12V18AH)

Specification:

Nominal Voltage(V) 12V
Nominal Capacity 18.0AH
Approx Weight Approx 5.4kg (11.9lbs)
Terminal T3/T12
Container Material ABS
Max. Discharge Current 270A (5s)
Internal Resistance Approx 16mÙ
Operating Temp.Range Discharge : – -15~50 C (5~122 F),  Charge :  0~40 C (32~104 F), Storage :  -15~40 C (5~104 F)
Nominal Operating Temp. Range 25 3 C (77 5 F )
Cycle Use Initial Charging Current less than 5.4A.Voltage 0 0 0 14.4V~15.0V at 25 C(77 F)Temp. Coefficient -30mV/ C
Standby Use No limit on Initial Charging Current Voltage 0 0 0 13.5V~13.8V at 25 C(77 F)Temp. Coefficient -20mV/ C
Capacity affected by Temperature
40 C (104 F) 103%
25 C ( 77 F) 100%
0 C ( 32 F) 86%
Rated Capacity
18.0 AH/0.90A (20hr ,1.80V/cell,25 C/77 F)
16.7 AH/1.67A (10hr,1.80V/cell,25 C/77 F)
15.1 AH/3.03A (5hr,1.75V/cell,25 C/77 F)
13.5 AH/4.49A (3hr,1.75V/cell,25 C/77 F)
11.1 AH/11.1A (1hr,1.60V/cell,25 C/77 F)